Proportional Electro-Hydraulic Pilot Relief Valves      

PDF

[!–VMCatalog{div class=”product-image float-left;” style=”width:30%;”}–]

EDG-01

[!–VMCatalog{div style=”text-align:justify;”}–]

[!–VMCatalog{/div}–]

[!–VMCatalog{/div}–]

[!–VMCatalog{div class=”ordering-code” style=”width:68%;”}–]

Note :

1. It is recommended that the return pipe is connected directly back to tank below the fluid level.

2. The specification chart to the right relates to performance achievable using HNC standard electronic controller type HNC-1085 and a pump flow of 2 lpm at oil temperature 45°C / 113°F and viscosity 45 cSt.

[!–VMCatalog{/div}–]

[!–VMCatalog{div class=”clear-fix”}/–]

[!–VMCatalog{div id=”product-tabs”}–]

[!–VMCatalog{div id=”tab-1″}–]

Dimensions

[!–VMCatalog{div style=”margin-top: 30px;”}–]

Proportional Electro-Hydraulic Pilot Relief  Valves – Dimensions

EDG Proportional Valves DimensionsEDG Proportional Valves Dimensions

[!–VMCatalog{/div}–]

[!–VMCatalog{/div}–]

[!–VMCatalog{div id=”tab-2″}–]

Performance Curves

[!–VMCatalog{div style=”margin-top: 30px;”}–]

EDG-01 Proportional Electro-Hydraulic Pilot Relief Valves

EDG Proportional Valves Performance Curves

[!–VMCatalog{/div}–]

[!–VMCatalog{/div}–]

[!–VMCatalog{div id=”tab-3″}–]

EDG-01 Proportional Electro-Hydraulic Pilot Relief Valves Operating Data

[!–VMCatalog{div style=”margin-top: 30px;”}–]

Position For Installation:

To install the pilot valve correctly mount with “bleed” up-wards in order to eliminate air and reduce the risk of air entrapment when used in conjunction with another main proportional valve.For a steady control pressure ensure that the pilot pressure pipe hoses does not exceed 30 cm.

Elimination Of Air(Air Vent) :

Set the pilot control pressure to 29.4bar(420PSI) and oper the bleed screw to eliminate the air.Lock the bleed screw when all air bubbles have been eliminated.

Manual Over-Ride:

It is possible to set the control pressure manually for commissioning and trouble shooting purposes.

Drain

Ensure that the return oil is piped back to tank directly and below the oil level.

[!–VMCatalog{/div}–]

[!–VMCatalog{/div}–]

[!–VMCatalog{div id=”tab-4″}–]

EDG-01 Proportional Electro-Hydraulic Pilot Relief Valves General Information

[!–VMCatalog{div style=”margin-top: 30px;”}–]

  1. Simplified piping system as result of using only  one remote electrically operated pilot relief valve for multiple functions requiring different pressure settings.
  2. Step-less pressure control proportional to input current. 24V DC control and 0-10 volts reference single.
  3. Good response with executer to reduce resonance.
  4. Standard HNC electronic controller type HNC-1085 for best results.
  5. Standard electrical connector to DIN 43650 (ISO4400).

[!–VMCatalog{/div}–]

[!–VMCatalog{/div}–]

[!–VMCatalog{div id=”tab-5″}–]

Ordering Code

EDG 01 C 20 *
Series No Valve Size Pressure Design No. Date Manufactured
Proportional Electro-Hydraulic Pilot Relief Valve G Type

EDG-01 Graphic Symbol

C : 137bar (1950PSI)

20 : With DIN 912 Bolts

H : 206bar (2930PSI) 2090 : With UNC(North American) Bolts

[!–VMCatalog{/div}–]

[!–VMCatalog{div id=”tab-6″}–]

[!–VMCatalog{div style=”margin-top:15px”}–]

Ratings

Model No. Max. Operating Pressure Max. Flow Min. Flow Pres. Adj. Range Rated Current Coil Resistance

(At 20°C/35.2°F)

Hysteresis Repeatability Weight
bar (PSI) lpm (USgpm) lpm (USgpm) bar (PSI) mA Ω kg (lbs)
EDG-01 250 (3600) 2 (0.53) 0.3 (0.08) C : 8~140 C : 750 10 < 3% < 0.5% 2 (4.4)
H : 10~210 H : 700

[!–VMCatalog{/div}–]

[!–VMCatalog{/div}–]

[!–VMCatalog{/div}–]

PDF