PVF | -12 | -70 | -11 | ||
---|---|---|---|---|---|
Series No. | Outlet Flow (lpm) at 3.5 bar, 1800 rpm | Operating Pressure range (bar) | Design No. | ||
PVF
Flange Mounting |
Code | Outlet Flow (lpm) | Code | Pressure Range | |
12 | 12 lpm | 20 | 8 ~ 20 bar | ||
20 | 20 lpm | 35 | 15 ~ 35 bar | ||
30 | 30 lpm | 55 | 30 ~ 55 bar | ||
40 | 40 lpm | 70 | 55 ~ 70 bar | ||
Factory Setting Qmax. | Factory Setting Pmin. |
[!–VMCatalog{/div}–]
[!–VMCatalog{div class=”clear-fix”}/–]
[!–VMCatalog{div id=”product-tabs”}–]
[!–VMCatalog{div id=”tab-1″}–]
Operating Data
[!–VMCatalog{div style=”margin-top: 10px;margin-bottom: 20px;”}–]
ROTARY DIRECTION
Clockwise rotation viewed from shaft end is standard.
[!–VMCatalog{/div}–]
[!–VMCatalog{div style=”margin-bottom: 20px;”}–]
FLUIDS PERMISSIBLE
When working pressure lower than 70 bar, hydraulic oil with a viscosity ranging from 30~50 cSt(ISO VG32). When working pressure higher than 71 bar .hydraulic oil with a viscosity ranging from 50-70 cSt(ISO VG68) at 40°C is recommended.(ISO VG32) at 40 °C is recommended.
[!–VMCatalog{/div}–]
[!–VMCatalog{div style=”margin-bottom: 20px;”}–]
DRAIN PORT PIPING
Drain connection must be piped directly to tank and below the oil level with a back pressure not exceed 0.3 bar.
[!–VMCatalog{/div}–]
[!–VMCatalog{div style=”margin-bottom: 20px;”}–]
OIL TEMPERATURE RANGE
Oil temperature range should be between 15-60°C for continuous operation and should be higher than 7°C at starting.
[!–VMCatalog{/div}–]
[!–VMCatalog{div style=”margin-bottom: 20px;”}–]
ALIGNMENT AND INSTALLATION OF PUMP
The shaft alignment for pump and electric motor shall be limited to 0.05mm TIR. and 1 degree angular error.
[!–VMCatalog{/div}–]
[!–VMCatalog{div style=”margin-bottom: 20px;”}–]
INLET PORT PRESSURE
Inlet port pressure should be -0.3 bar to +0.3 bar.
[!–VMCatalog{/div}–]
[!–VMCatalog{div style=”margin-bottom: 20px;”}–]
FLOW ADJUSTMENT
The flow will be reduced when the flow adjusting screw is turned clockwise and increased when anti-clockwise.
[!–VMCatalog{/div}–]
[!–VMCatalog{div style=”margin-bottom: 20px;”}–]
PRESSURE ADJUSTMENT
The pressure will be increased when the pressure adjusting screw is turned clockwise and reduced when anti-clockwise.
P-Q CHARACTERISTICS ( EX-WORK SET ) Flow setting:The max. flow as catalogue shown. Pressure setting:The min. operating pressure range.
[!–VMCatalog{/div}–]
[!–VMCatalog{div style=”margin-bottom: 20px;”}–]
SLIDE SCREW
The slide screw is non-adjustable and set at factory. Unauthorized persons cannot tamper with the desired setting.
[!–VMCatalog{/div}–]
[!–VMCatalog{div style=”margin-bottom: 20px;”}–]
CAUTIONS FOR STARTING
Start up the pump under No-Load condition and repeat to start and stop the motor several times to extract the air from inside of the pump and piping.Then keep a 10 minutes continuous running for a better de-airing.
[!–VMCatalog{/div}–]
[!–VMCatalog{div}–]
PEAK-PRESSURE
The peak pressure is 140 bar for code * 2 & * 3,and 210 bar for A4 & A5.
[!–VMCatalog{/div}–]
[!–VMCatalog{/div}–]
[!–VMCatalog{div id=”tab-2″}–]
Performance Curves
[!–VMCatalog{div style=”width: 49%; margin-right: 2%; float: left; margin-top: 20px;”}–]
[!–VMCatalog{/div}–]
[!–VMCatalog{div style=”width: 49%; float: left; margin-top: 20px;”}–]
[!–VMCatalog{/div}–]
[!–VMCatalog{div class=”clear-fix”}/–]
[!–VMCatalog{div style=”width: 49%; margin-right: 2%; float: left; margin-top: 20px;”}–]
[!–VMCatalog{/div}–]
[!–VMCatalog{div style=”width: 49%; float: left; margin-top: 20px;”}–]
[!–VMCatalog{/div}–]
[!–VMCatalog{div class=”clear-fix”}/–]
[!–VMCatalog{div style=”width: 49%; margin-right: 2%; float: left; margin-top: 20px;”}–]
[!–VMCatalog{/div}–]
[!–VMCatalog{div style=”width: 49%; float: left; margin-top: 20px;”}–]
[!–VMCatalog{/div}–]
[!–VMCatalog{div class=”clear-fix”}/–]
[!–VMCatalog{div style=”width: 49%; margin-right: 2%; float: left; margin-top: 20px;”}–]
[!–VMCatalog{/div}–]
[!–VMCatalog{div style=”width: 49%; float: left; margin-top: 20px;”}–]
[!–VMCatalog{/div}–]
[!–VMCatalog{div class=”clear-fix”}/–]
[!–VMCatalog{/div}–]
[!–VMCatalog{div id=”tab-3″}–]
Assembly
Parts List:
[!–VMCatalog{div style=”width: 49%; margin-right: 1%; float: left;”}–]
No. | Part Name | Specification | Quantity |
---|---|---|---|
1 | Retainer Ring | R28 | 1 |
2 | Shaft Seal | TCV 14287 | 1 |
3 | Pump Body | 1 | |
4 | Slide Screw | 1 | |
5 | O-Ring | 1A-P8 | 1 |
6 | Hexagon Nut | 1 | |
7 | Plastic Plug | 1 | |
8 | Piston | 1 | |
9 | Spring | 1 | |
10 | O-Ring | 1A-P20 | 1 |
11 | Spring Retainer | 1 | |
12 | Cover | 1 | |
13 | Socket Head Cap Screw | M6xP1.0x20L | 2 |
14 | Socket Set Screw | M10xP1.5x35L | 1 |
15 | Hex Nut | M10xP1.5 | 1 |
16 | Spring Pin | ø3×8 | 1 |
16-1 | Spring Pin | ø3×8 | 2 |
17 | Straight Pin | ø3×8 | 2 |
[!–VMCatalog{/div}–]
[!–VMCatalog{div style=”width: 49%; float: left;”}–]
No. | Part Name | Specification | Quantity |
---|---|---|---|
18 | Engine Bush | DIADO(Japan)DD1415 | 1 |
18-1 | Engine Bush | DIADO(Japan)DD1415 | 1 |
19 | Port Plate | 1 | |
20 | Rotorshaft | 1 | |
21 | Vanes | 13 | |
22 | Cam Ring | 1 | |
23 | Thrust Plate | 1 | |
24 | O-Ring | AS568-031 | 1 |
25 | Endless Back-up Ring | 1 | |
26 | O-Ring | AS568-023 | 1 |
27 | Endless Back-up Ring | 1 | |
28 | O-Ring | 1A-S71 | 1 |
29 | Cover | 1 | |
30 | Socket Head Cap Screw | M8xP1.25x30L | 4 |
31 | Name Plate | 1 | |
32 | Fixing Screw | 3 | |
33 | Woodruff Key | No. 406 | 1 |
34 | Washer | M10 | 2 |
35 | Hexagon Screw | M10xP1.5x25L | 2 |
[!–VMCatalog{/div}–]
[!–VMCatalog{div class=”clear-fix”}/–]
[!–VMCatalog{/div}–]
[!–VMCatalog{div id=”tab-4″}–]
Dimensions
PVF-12 Dimensions
PVF-30(40) Dimensions
[!–VMCatalog{/div}–]
[!–VMCatalog{/div}–]